Military MIL-STD-202 Test Test Method Condition Thermal shock 107 A Humidity 103 B Saltspray 101 A Shock 213 H Vibration 201 None Terminal strength 211 A (5 lbs.) Because the operation of the Sonalert audible signal device is dependent upon the circuit in which it is used, it is advisable to thoroughly test the selected device in the specific circuit and application to assure mechanical and electrical compatibility and verify system performance.
----------------------------------------------------------------------------------------------------------------------
                                                             Minimum                                  Typical
Catalog    Loudness     Mounting     Case   Frequency    Sound Pressure        Operating Voltage     Operating
Number     Category      Method      Style  +/-500 Hz   dB (A) at Two Feet     *AC/DC Non-polar      Current mA
                                                       At Min. V / At Max. V   ** Min.   Max.    At Min. V / At Max. V
----------------------------------------------------------------------------------------------------------------------
#SC616MN    Loud          Panel       C-8      2900        80           95           6     16        6          22 
 SC628MN    Loud          Panel        C       2900        80           90           6     28        4          16 
 SC628M     Medium        Panel        C       2900        68           80           6     28        3          14 
 SC628MD    Medium        Panel        C       1900        60           75           6     28        3          14 
 SC628MH    Medium        Panel        C       4500        68           80           6     28        3          14 
 SC648M     Medium        Panel        C       2900        68           80          10     48        3          14 
 SC648MD    Medium        Panel        C       1900        60           75          10     48        3          14 
 SC628MA    Medium        Panel        D       2900        68           80         * 6     28        4          16 
 SC628MAH   Medium        Panel        D       4500        68           80         * 6     28        4          16 
 SC648MA    Medium        Panel        D       2900        68           80         *10     48        4          16 
 SC648MAH   Medium        Panel        D       4500        68           80         *10     48        4          16 
 SC11OM     Medium        Panel        D       2900        68           80         *30    120        4          16 
 SC11OMH    Medium        Panel        D       4500        68           80         *30    120        4          16 
 SC250M     Medium        Panel        D       2900        68           80         *60    250        4          16 
# Denotes new product
Turns on and off at 2 to 9 pulses per second depending upon voltage at 50% duty cycle. SC628MNP Loud Panel D 2900 80 90 6 28 4 16 SC628MP Medium Panel D 2900 68 80 6 28 3 14 SC628MHP Medium Panel D 4500 68 80 6 28 3 14
Produces two tones alternately when used with additional continuous unit. SC628MW Medium Panel D-1 2900 68 80 6 28 3 16
Dual mode operation. SC616MPU Medium Panel C-7 2900 68 78 6 16 3 12 * For both DC or AC Operation (AC Voltage is RMS for 50 or 60 Hz Power Line) ** Minimum voltage specified for sound test does not represent sound turn-on or turn-off points. Units will sound at lower voltages.
| 
 | 
 | 
 | 
| 
 | 
 | 
 | 
![]()  | 